beautypg.com

Rma-303 indirect charge - maintenance – Ransburg RMA Indirect A12869 User Manual

Page 78

background image

RMA-303 Indirect Charge - Maintenance

73

LN-9268-11.4

Figure 48: Valve Extraction

Figure 49: Valve Extraction

Figure 50: Fiber Optic Removal/Replacement

Fiber Optic Cable and Transmitter Remov-
al/Replacement

Removal

Remove the atomizer body from the atomizer
extension as discussed earlier.

Remove the fiber optic nut from the inside
cavity where the air bearing spindle seats us-
ing the fiber optic transmitter tool (78279-00).
Loosen and remove nut. Carefully pull out the
fiber optic transmitter from the front while
pushing the cable from the opposite end.
Loosen the black knurled nut holding the ca-
ble to the transmitter. Pull the nut off of the
cable. The cable can be pulled out from the
back side of the atomizer body.

Replacement

To replace, slide the new fiber optic cable
through the hole in the back side of the atom-
izer body until it protrudes well out in front of
the body. Slide the black knurled nut over the
fiber optic cable approximately 1/4-inch (onto
the black portion of the cable). Install the
glass fiber portion into the rear of the transmit-
ter until it bottoms. Slide the nut forward and
tighten securely. Slide the entire assembly
back into the atomizer body. Pull gently from
the back side while pushing the transmitter
from the front. Slide fiber optic nut over trans-
mitter and tighten securely with transmitter tool
(78279-00). Feel transmitter after installation.
It should not be loose when properly installed.

QUICK RELEASE COLLET REMOVAL AND
REPLACEMENT
(Atomizer Body and Cup Wash Manifold)
(Figure 51)

If collet or O-rings become damaged, they can
be removed and replaced. To remove the cul-
let, use a flat blade screwdriver or needle nose
pliers. If using the screwdriver, lift cullet with
fingers and place screwdriver blade under the
head. Pry up in several places if necessary
until removed. If using the pliers, grasp the
head between the inside and outside diameter
and pull straight out or by pulling with a rocking
motion.