Rma-303 indirect charge - introduction – Ransburg RMA Indirect A12869 User Manual
Page 17
RMA-303 Indirect Charge - Introduction
LN-9268-11.4
12
Mechanical (Cont.)
Maximum Angular Velocity
for Turbine (Robot Motion):
250
°
/sec.
Shaping Air #1 (SAI)
Supply:
Variable (See "Pressure Flow Data Charts" in this section.)
Shaping Air #2 (SAO)
Supply:
Variable
(See "Pressure Flow Data Carts" in this section.)
Brake Air Supply:
60-100 psig
(Nominal):
(414-689 kPa)
Maximum Fluid Pressure Supply:
Paint:
200 psi (1379 kPa)
Solvent:
150 psi (1035 kPa)
Fluid Flow Rate:
25-700 cc/min.
Bell Cup Cleaning Time
(Internal/External):
2-7 sec. (Approx.)
Color Change Time:
Dependent on system configuration, fluid pressures, fluid vis-
cosity, fluid line lengths, etc.
Speed Readout:
Magnetic pick-up, unidi-rectional fiber optic transmission
Bell Cup Replacement
Time:
Less than 2 minutes
Minimum Control Equipment
Requirements:
Versions listed or higher)
MicroPak
LECU5004-17 (V3.84)
Atomizer Module
A11925-00 (V 0.4)
I/O Module
A11435-00 (V1.4) (0-10V) (4-20 mA)
•
Specifications and ratings based on testing at sea level standard conditions.
•
Tubing Bundle Max. 450
°
Rotation in either Direction.