RMA-303 Indirect Charge - Maintenance
LN-9268-11.4
60
!
W A R N I N G
N O T E
Figure 19: Atomizer Removal
HIGH VOLTAGE CONNECTIONS FOR
SHIELDED/
NON-METALLIC CORE CABLE - A10560-
XX
>Remove curved tube (A11691-00) and lock-
nut (A11318-00) to ensure proper grooves are
filled with dielectric grease before cable instal-
lation (see Figures 16 or 49). Remove and
clean any excess grease after assembly.
High Voltage Connection - Cascade End
Insert end of cable (end of cable with the
green grounding wire attached) thru compres-
sion nut of output tube of RansPak™ cascade
(74793-01 or 74793-02) until it bottoms into
banana jack receptacle. Tighten compression
nut by hand, then tighten 1/2 turn more with a
wrench. DO NOT over-tighten as this may
damage cable.
Secure green wire with yellow stripe (attached
to high voltage cable) to any known good
earth ground, such as a water pipe, etc., using
the attached ring terminal.
>
Arcing/fire hazard exists if ungrounded met-
al connections (air or fluid) are used in the
spray area. Use plastic nonconductive con-
nections, or ensure metal connections are at
ground potential.