MMA-303 Direct/Indirect Charge - Maintenance
75
LN-9269-11.3
then tighten 1/2 turn more with a wrench. DO
NOT
over-tighten as this may damage cable.
Secure green wire with yellow stripe (attached
to high voltage cable) to any known good
earth ground, such as a water pipe, etc., using
the attached ring terminal.
DISASSEMBLY PROCEDURES
(Cont.)
Bell Cup Removal / Replacement
The bell cup should always be the first compo-
nent removed if any maintenance is per-
formed. Following the procedure will minimize
the risk of damage to the cup itself.
Lay the applicator on its side of a clean and
secure area, preferably an area where regular
maintenance is performed. Using the large
open end of the ball cup/combo wrench
(A12601-00) on the flats of the turbine shaft,
carefully hold the outside of the bell cup with
one hand while applying a clockwise force to
the wrench. The bell cup is a right hand thread
and must be turned counter-clockwise to re-
move.
Atomizer Removal
N O T E
Bell Cup Removal
Place the bell cup in a safe, secure place.
Carefully inspect the cup for any damage. If
there is any damage to the cup, it must be re-
placed.
!
C A U T I O N
•
Failure to replace a damaged bell cup will
cause premature turbine failure. Warranty
will not be honored if the bell cup is dam-
aged.
N O T E
For removal of the 30mm or 55mm bell cups,
you must use bell cup wrench A11284-00.
For the 65mm bell cups you must use
AA12061-00 bell cup wrench.
A11284-00 BELL CUP WRENCH
A12061-00 BELL CUP WRENCH
USE ON 30M AND 55MM BELL CUPS ONLY
USE ON 65MM BELL CUPS ONLY
Bell Cup Wrenches