MMA-303 Direct/Indirect Charge - Maintenance

LN-9269-11.3

98

General Problem

Possible Causes

Corrective Action

Low or No High

7. Faulty low voltage connections 7. Make sure quick disconnect electrical

Voltage (Cont.)

(Usually indicated by MicroPak connection is aligned and clean.

feedback fault light)

a. Check low voltage connection at cascade.

8. Faulty high voltage connection 8. a. Remove cascade and check continuity

between cascade connection and turbine

shaft.

9. MicroPak or cascade failure

9. Refer to "MicroPak" service manual for

detailed "Troubleshooting Guide".

10. Improper color change

10. Optimize color change.

(i.e., paint or solvent in dump

line)

Low Transfer

1. Low or no high voltage

1. Verify high voltage at bell cup edge. Normal-
ly

Efficiency (or light

a high voltage setting of 70-100 kV is

coverage)

appropriate for most applications.

2. Poor grounding of parts being 2. Verify that parts being coated are properly

coated

grounded (the electrical resistance between

the part and ground must not exceed

1 megohm).

3. Excessive turbine speed

3. For optimum transfer efficiency and spray

pattern control, the bell rotational speed

should be set at the minimum required to

achieve proper atomization of the coating

material.

4. Excessive inner/outer shaping 4. Shaping air should be set at the minimum

air

volume required to gently direct the spray

pattern toward the part being coated.

Excessive shaping air will cause some

atomized particles to "blow-by" the part or

bounce back onto the atomizer.

5. Excessive target distance

5. The recommended target distance is be-
tween

6-12 inches (152.4-304.8 Nm) (see "Target

Distance" in the "Operation" section of this

manual).

No Turbine Air

1. Turbine drive air not present

1. Verify supply air pressure.

2. Bearing air return signal not

2. a. Verify bearing air return signal.

present

b. Increase bearing air supply pressure to

90 psig (± 10 psig) (620.5 ± 68.9 kPa).

3. Brake air is activated

3. Remove brake air signal (turbine air and

brake air must be interlocked to prevent

both from being used simultaneously).

Troubleshooting Guide — Direct Charge (Cont.)