MMA-303 Direct/Indirect Charge - Maintenance
LN-9269-11.3
70
MMA-303 PREVENTIVE MAINTENANCE SCHEDULE
Frequency (Maximum)
Procedure
Mid-Shift End of Shift
Weekly
2
Weeks Monthly 3 Months 6 Months
Yearly
Mid Shift Cleaning
X
• Wipe electrodes
• Wipe shroud
• Visually inspect cup
End of Shift Cleaning
X
• Wipe electrodes
• Wipe shroud
• Wipe bell cup down
• Change cloth cover
Shaping Air Shroud
X
X
X
• Clean inner shape air ring
• Clean outer shape air ring
• Remove and clean
Bell cup removal/
inspection/
X
X
cleaning
Fluid Tip inspection/
cleaning
X
X
Inspect Valve and Seat
X
Assembly in Valve Module
for leaking
Replace Valves and Seats
X
in Valve Module
High Voltage Cable
X
X
Inspections
High Voltage Testing
X
Regreasing of High Voltage
X
Cables
Check resistance of High
X
Voltage Electrodes
Regreasing Electrode
X
Cavities of High Voltage
Ring and High Voltage In-
put
Inspect all Screws
X
• Replace if broken
• Inspect for wear
• Tighten per specifications