SPECIFICATIONS - Electrical / Mechanical
Electrical
Power Supply Type:
MicroPak
Charging Method:
Direct and Indirect
Output Voltage:
100 kV Maximum - Direct
// 30-70 kV Variable - Indirect
Output Current:
1000 µA
Turbine Speed Control:
Atomizer Module
Part Spray ability:
Determine spray ability of part to be coated using Test Equip-
ment (76652) (Paint Conductivity Meter)
Mechanical
Length:
(See “MMA-303 Tool Center Point Dimension” figures in the
“Introduction” section.)
Diameter:
(See “MMA-303 Tool Center Point Dimension” figures in the
“Introduction” section.)
Approximate Weight:
(See “MMA-303 Tool Point Dimension” figures in the
“Introduction” section.)
Turbine Type:
Air Bearing Impulse Drive
Turbine Air Supply:
Variable (See “Pressure Flow Data Charts” in the
“Introduction” section.)
Maximum/Minimum
Turbine Speed:
Continuous 70K rpm max./20K rpm min.
Maximum Angular Velocity
for Turbine (Robot Motion):
250˚/sec.
Bearing Air Supply
at the Applicator:
90 psig (±10 psi)
(Nominal):
621 kPa ± 69 kPa)
2.9 SCFM (82 slpm)
Shaping Air #1 (SAI) Supply:
Variable (See “Pressure Flow Data Charts” in the
“Introduction” section.)
Shaping Air #2 (SAO) Supply:
Variable (See “Pressure Flow Data Charts” in the
“Introduction” section.)
Brake Air Supply:
60-100 psig
(Nominal):
(414-689 kPa)