Troubleshooting Guide (Cont.)

General Problem

Possible Cause

Solution

No Shaping Air At

Applicator

No Bearing Air To

Applicator

1. Remote manifold main air input

off

2. No SHP output from Aerobell

Control Unit

3. Improper tubing connection

4. Defective volume booster on

remote manifold

1. Remote manifold main air input

off

2. Improper tubing connection

3. Defective bearing air filter

1. Turn remote manifold main air input

on.

2. See "No SHP air output" on previous

page.

3. Correct tubing connection.

4. Replace volume booster.

1. Turn remote manifold main air input

on.

2. Correct tubing connection.

3. Repair or replace bearing air filter.