OPERATION
(Refer to Figure 8)
Turn supply air on to the remote manifold and con-
trol module. The following controls are available
from the front panel. (Adjust control settings as
described in the applicator service manual.)
OPERATING CONTROLS
Fluid
Adjusting the FLD knob on the front panel adjusts
the pilot air pressure to the fluid regulator at the
applicator, thereby allowing flow rate adjustment of
the material being sprayed. A FLD gauge on the
front panel displays the current pressure setting
of this signal. A FLD ON/OFF switch can be used
to turn this signal ON or OFF.
>
Operators must be fully trained in safe
operation of electrostatic equipment. Oper-
ators must read all instructions and safety
precautions prior to using this equipment
(see NFPA-33).
W A R N I N G
!
Shaping Air
Adjusting the SHP knob on the front panel adjusts
the pilot air pressure to the shaping air volume
booster at the remote manifold. The output of
the volume booster is connected to the applicator
shaping air input, thus adjustment of the SHP knob
allows adjustment of applicator shaping air. A
SHP gauge on the front panel displays the current
pressure setting of this signal. A SHP ON/OFF
switch can be used to turn this signal ON or OFF.
Atomization/Turbine Air
Adjusting the ATM knob on the front panel adjusts
the pilot air pressure to the atomization air volume
booster at the remote manifold. The output of the
volume booster is connected to the applicator at-
omization/turbine air input, thus adjustment of the
ATM knob allows adjustment of applicator turbine
speed, which controls atomization. An ATM gauge
on the front panel displays the current pressure
setting of this signal. An ATM ON/OFF switch can
be used to turn this signal ON or OFF.
Trigger Air On/Off Switch
When this switch is turned on, an air signal is
sent to the applicator to open the trigger valve
and allow fluid flow.
Dump Air On/Off Switch
When this switch is turned on, an air signal is sent
to the applicator to open the dump valve. The
dump valve can be used to quickly flush material
out of the system without having to atomize it
into the booth. This usually results in lower VOC
emissions as well. Once most of the system has
been flushed through the dump valve, a short push
of solvent through the applicator can be used to
clean the applicator.
Solvent Air On/Off Switch
(Aerobell 33 Version Only)
When this switch is turned on, an air signal is
sent to open the applicator and flush manifold
solvent valves.
>
All air switches bleed off output air
when switched off.
NOTE
9040 Aerobell Control Module - Operation