OPERATION

(Refer to Figure 8)

Turn supply air on to the remote manifold and con-

trol module. The following controls are available

from the front panel. (Adjust control settings as

described in the applicator service manual.)

OPERATING CONTROLS

Fluid

Adjusting the FLD knob on the front panel adjusts

the pilot air pressure to the fluid regulator at the

applicator, thereby allowing flow rate adjustment of

the material being sprayed. A FLD gauge on the

front panel displays the current pressure setting

of this signal. A FLD ON/OFF switch can be used

to turn this signal ON or OFF.

>

Operators must be fully trained in safe

operation of electrostatic equipment. Oper-

ators must read all instructions and safety

precautions prior to using this equipment

(see NFPA-33).

W A R N I N G

!

Shaping Air

Adjusting the SHP knob on the front panel adjusts

the pilot air pressure to the shaping air volume

booster at the remote manifold. The output of

the volume booster is connected to the applicator

shaping air input, thus adjustment of the SHP knob

allows adjustment of applicator shaping air. A

SHP gauge on the front panel displays the current

pressure setting of this signal. A SHP ON/OFF

switch can be used to turn this signal ON or OFF.

Atomization/Turbine Air

Adjusting the ATM knob on the front panel adjusts

the pilot air pressure to the atomization air volume

booster at the remote manifold. The output of the

volume booster is connected to the applicator at-

omization/turbine air input, thus adjustment of the

ATM knob allows adjustment of applicator turbine

speed, which controls atomization. An ATM gauge

on the front panel displays the current pressure

setting of this signal. An ATM ON/OFF switch can

be used to turn this signal ON or OFF.

Trigger Air On/Off Switch

When this switch is turned on, an air signal is

sent to the applicator to open the trigger valve

and allow fluid flow.

Dump Air On/Off Switch

When this switch is turned on, an air signal is sent

to the applicator to open the dump valve. The

dump valve can be used to quickly flush material

out of the system without having to atomize it

into the booth. This usually results in lower VOC

emissions as well. Once most of the system has

been flushed through the dump valve, a short push

of solvent through the applicator can be used to

clean the applicator.

Solvent Air On/Off Switch

(Aerobell 33 Version Only)

When this switch is turned on, an air signal is

sent to open the applicator and flush manifold

solvent valves.

>

All air switches bleed off output air

when switched off.

NOTE