MAINTENANCE

MONTHLY MAINTENANCE

1. Remove the Aerobell Control Unit from the rack

and inspect air lines for defects.

2. Replace any faulty items. Inspect air bowls on

main air inputs. Drain them and replace filters if

necessary.

TROUBLESHOOTING GUIDE

(Refer to Figures 9 & 10)

General Problem

Possible Cause

Solution

Improper Air Output or

Input

System Operates OK,

But Gauge Does Not

Read

No Fluid (FLD) Air

Output

No High Voltage (HV)

Air Output

No Dump Air Output

1. Main line air off

2. Loose fitting

3. Defective tubing

1. Clogged or cracked tubing

2. Defective gauge

1. Main line air off

2. FLD air toggle switch off

3. Defective FLD regulator REG1

4. Defective FLD toggle switch

SW1

1. Dump or solvent output active

2. Defective air valve PV3

1. Electrostatic power supply on

2. Dump air toggle switch off

3. Defective dump toggle switch

SW4

1. Turn on main line air.

2. Tighten fitting.

3. Replace defective tubing.

1. Replace defective tube.

2. Replace defective gauge.

1. Turn on main line air.

2. Turn FLD air toggle switch on.

3. Replace regulator REG1.

4. Replace toggle switch SW1.

1. Turn off dump or solvent air toggle

switch.

2. Replace air valve PV3.

1. Turn electrostatic power supply off.

2. Turn dump air toggle switch on.

3. Replace toggle switch SW4.