General Problem
Possible Cause
Solution
No Solvent Air Output
(Aerobell 33 Version
Only)
No Trigger (TRG) Air
Output
No Atomization (ATM)
Air Output
No Shaping (SHP) Air
Output
No Turbine Air At
Applicator
1. Electrostatic power supply on
2. Atomization (ATM) air output off
3. Solvent air toggle switch off
4. Defective solvent toggle switch
SW5
5. Defective air valve PV1
1. Atomization (ATM) air output off
2. TRG air toggle switch off
3. Defective TRG toggle switch
SW6
4. Defective air valve PV2
1. No bearing air (BA) input
2. ATM air toggle switch off
3. Defective ATM toggle switch
SW3
4. Defective bearing air sense
valve SNS1
5. Defective ATM regulator REG3
1. SHP air toggle switch off
2. Defective SHP toggle switch
SW2
3. Defective SHP regulator REG2
1. Remote manifold main air input
off
2. No ATM output from Aerobell
Control Unit
3. Improper tubing connection
4. Defective volume booster on
remote manifold
1. Turn electrostatic power supply off.
2. Activate ATM air output.
3. Turn solvent air toggle switch on.
4. Replace toggle switch SW5.
5. Replace air valve PV1.
1. Activate ATM air output.
2. Turn TRG air toggle switch on.
3. Replace toggle switch SW6.
4. Replace air valve PV2.
1. Activate bearing air.
2. Turn ATM air toggle switch on.
3. Replace toggle switch SW3.
4. Replace sense valve SNS1
5. Replace regulator REG3
1. Turn SHP air toggle switch on.
2. Replace toggle switch SW2.
3. Replace regulator REG2.
1. Turn remote manifold main air input
on.
2. See "No ATM air output" above.
3. Correct tubing connection.
4. Replace volume booster.
Troubleshooting Guide (Cont.)
9040 Aerobell Control Module - Operation
23
Ransburg
CP-02-01.2