Ransburg, Electrical connections, Pneumatic connections – Ransburg 9040 Aerobell Control Module 78387-00 User Manual
Page 15

ELECTRICAL
CONNECTIONS
HV Solenoid Cable
Connect the 3 foot 78386-00 cable assembly
(supplied) from 1REC at the rear of the Aerobell
Control Unit to 2SOC at the rear of the 9040 Cas-
cade Low Voltage Module (see Figure 4).
Ground Wire Assembly
Ensure that the 70539-00 Ground Wire Assembly
(see Figure 4) is connected from the enclosure
housing the Aerobell Module, to a true earth
ground.
PNEUMATIC
CONNECTIONS
Referring to Figures 2, 3, 5, 6, and 7 make the fol-
lowing pneumatic connections (these connec-tions
are shown in "Pneumatic Connections"chart in the
"Installation" section):
Control Module
"MAIN"
Main line air supply connection to the control mod-
ule. Using 1/4-inch OD tubing, connect “MAIN”
input to a source of clean, filtered factory air.
"HV"
Air output that ensures AC voltage to the low volt-
age module is OFF during dump or solvent flush
operations. Using 1/4-inch OD tubing, connect
“HV” output to 3PS on rear of the low voltage
module (see Figure 4).
>
This cable
MUST be connected to
ensure that the solvent or dump functions
of the Aerobell Module cannot be activated
when high voltage is present.
W A R N I N G
!
Figure 4: Electrical Connections
9040 Aerobell Control Module - Installation
12
Ransburg
CP-02-01.2