ELECTRICAL

CONNECTIONS

HV Solenoid Cable

Connect the 3 foot 78386-00 cable assembly

(supplied) from 1REC at the rear of the Aerobell

Control Unit to 2SOC at the rear of the 9040 Cas-

cade Low Voltage Module (see Figure 4).

Ground Wire Assembly

Ensure that the 70539-00 Ground Wire Assembly

(see Figure 4) is connected from the enclosure

housing the Aerobell Module, to a true earth

ground.

PNEUMATIC

CONNECTIONS

Referring to Figures 2, 3, 5, 6, and 7 make the fol-

lowing pneumatic connections (these connec-tions

are shown in "Pneumatic Connections"chart in the

"Installation" section):

Control Module

"MAIN"

Main line air supply connection to the control mod-

ule. Using 1/4-inch OD tubing, connect “MAIN”

input to a source of clean, filtered factory air.

"HV"

Air output that ensures AC voltage to the low volt-

age module is OFF during dump or solvent flush

operations. Using 1/4-inch OD tubing, connect

“HV” output to 3PS on rear of the low voltage

module (see Figure 4).

>

This cable

MUST be connected to

ensure that the solvent or dump functions

of the Aerobell Module cannot be activated

when high voltage is present.

W A R N I N G

!

Figure 4: Electrical Connections

9040 Aerobell Control Module - Installation

12

Ransburg

CP-02-01.2