Ransburg, Pneumatic connections, Control module – Ransburg 9040 Aerobell Control Module 78387-00 User Manual
Page 17: Remote manifold, Bearing air filter, 9040 aerobell control module - installation

CONTROL MODULE
Main Input
HV Output
FLD Output
ATM Output
ATMR Input
SHP Output
SHPR Input
BA Input
DMP Output
SOLV Output
SOLV Output
TRG Output
From
To
Tubing
Notes
Notes:
1. For standard RPM Aerobells, there is no bearing air output signal from the bell itself. In this case
insert a 1/4-inch OD tee fitting in the bearing air input line to the bell and connect the outlet of the tee
to "BA". Make this connection as close to the bell as possible.
2. This connection not used for RPM Aerobell versions.
3. Adhesive tape, pipe dope, or other thread sealant material should not be used downstream of the
bearing air filter.
4. 1/4-inch ODT tee fitting required.
Filtered Plant Air Supply
Low Voltage Module - 3PS
Applicator - Air Pilot Input of Fluid Regulator
Remote Manifold - Atomization Air Pilot Input
Remote Manifold - Atomization Air Gauge Output
Remote Manifold - Shaping Air Pilot Input
Remote Manifold - Shaping Air Gauge Output
Applicator - Bearing Air Output
Applicator - Dump Valve Air Input
Applicator - Solvent Valve Air Input
Solvent Flush Manifold - Air Input
Applicator - Trigger Valve Air Input
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1/4-inch PE
1
2, 4
2, 4
REMOTE MANIFOLD
Shaping Air
Regulator Output
Atomization Air
Regulator Output
Remote Manifold
Main Air Output
From
To
Tubing
Notes
Applicator - Shaping Air Input
Applicator - Atomization/Turbine Air Input
Bearing Air Filter - Air Input
3/8-inch PE
1/2-inch PE
3/8-inch PE
BEARING AIR FILTER
Bearing Air
Filter Output
From
To
Tubing
Notes
Applicator - Bearing Air Input
1/4-inch PE
3
PNEUMATIC CONNECTIONS
9040 Aerobell Control Module - Installation
14
Ransburg
CP-02-01.2