Command T

ype (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

<1A>

Not Used.

Not Used.

<1B>

Not Used.

Not Used.

<1C>

Request tLookup T

able data:

<1C><0G>

Where 1) = message length = <02h>. 2) = Gun #. 3) = Job #.

Response:

<1C>

Where: 1) = message length = <20h>. 2) <0G> = Gun #. 3) = Job #. 4) = Flow Rate for Entry #0. 5) = Output for Entry #0. 6) = Flow Rate for entry #1. 7) = Output for entry #1. 8) = Flow Rate for entry #2. 9) = Output for entry #2. 10) = Flow Rate for entry #3. 1

1) = Output for entry #3.

12) = Flow Rate for entry #4. 13) = Output for entry #4. 14) = Flow Rate for entry #5. 15) = Output for entry #5. 16) = Flow Rate for entry #6. 17) = Output for entry #6. 18) = Flow Rate for entry #7. 19) = Output for entry #7. 20) = Flow Rate for entry #8. 21) = Output for entry #8. 22) = Flow Rate for entry #9. 23) = Output for entry #9.