Command Type (hex)
Response Or
Action From User Interface
Response Or
Action From Interface Module
For Gun and Channel Codes, the gun or channel number appears in the lower nibble.
System Codes / Error Description: 0xB000
=
System
Halted
0xB010
=
Remote
I/O
(RIO)
Communication
Error
0xB020
=
Invalid
RIO
BTW
Code
0xB030
=
Invalid
RIO
BTR
code
0xB040
=
Invalid
RIO
BTW/BTR
Gun/Channel
Number
0xB050
=
Invalid
RIO
BTW/BTR
Job
Number
0xB060
=
Invalid
RIO
BTW
W
ord
Count
Gun Codes / Error Description: 0x202g
=
Pot
Life
T
ime
Exceeded
0x205g
=
Out
of
Ration
0x206g
=
Gun
Not
Ready
0x207g
=
Gun
Busy
0x908g
=
No
External
Gun
Enable
0xA02g
=
Flow
Rate
Out
of
Range
(Low
or
High)
Channel Codes / Error Description: 0x901c
=
Ratio
Out
of
T
olerance
0x902c
=
Reverse
Flow
V
olume
Exceeded
0x903c
=
Flow
Rate
T
oo
Low
0x904c
=
Flow
Rate
T
oo
Low
0x905c
=
Duplicate
Channel
Assigned
0x906c
-
Ki
Parameter
T
oo
Small
0x907c
=
No
Master
Flow
Rate
0x909c
=
Channel
Not
Present
0x91
1c
=
Out
of
T
olerance,
Slave
Flow
Rate
T
oo
High
0x921c
=
Out
of
T
olerance,
Slave
Flow
Rate
T
oo
Low
Note: If sent unsolicited, only
Type <06> message.
<08>
Request for Start Calibration for a Channel: <08>
Automatic Mode Calibration set point,
else <00><00>.
Response:
ACK