beautypg.com

Ransburg, Dynaflow, Programer's manual - introduction – Ransburg DynaFlow Programmers Manual User Manual

Page 44

background image

Command T

ype (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

Bit 13 = Bit 14 = Bit 15=

<16>

Request to Force

Analog Output:

<16>

Where: 1) = message length = <03h>. 2) <0C> = Channel #. 3) = D/A

Output #1

4) = D/A

Output #2.

Response:

ACK

Note:

The

Gun

that

the

Channel

is

co

nfigured

to

must

be

in Ready mode and not

Active.

The forced analog output

value must be returned to <00> before requesting that the (Gun) become Active.

<17>

Request for Current

Analog V

alues:

<17><0C>

Where: 1) = message length = <01h>. 2) <0C> = Channel #.

Response:

<17><0C>

A>

Where: 1) = message length = <07h>. 2) <0C> = Channel #. 3) =

Analog Input.

4) = Spare

Analog Input.

5)

A> =

Transducer

Analog Output

6) = Spare

Analog Output

<18>

Request to Rest Grand T

otal V

olume for a Channel for a Job:

<18><0C>

Where: 1) = message length = <02h>. 2) <0C> = Channel #. 3) = Job #.

Response:

ACK

<19>

Request to Reset Grand T

otal V

olume for a Channel for

All Jobs: <18><0C> Where: 1) = message length = <01h>. 2) <0C> = Channel #.

Response:

ACK

Note: W

ait 200 milliseconds before issuing another command to

allow the Interface Module time to complete the transfer

.

40

DynaFlow

Programer's Manual - Introduction

Ransburg

LN-9406-00.3