Unit specs, Vx pattern sizes – Kasco Marine VFX Series User Manual

Page 3

background image

3

Unit Specs

Model

Voltage Amps Lock

rotor

amps

Control

box con-

nection

Aerator

connec-

tion

single phase

aerators

2400VFX

110-120

5.6

12

C-25

plug in

Plug into

C-25

3400VFX

110-120

7.3

18

C-25

plug in

Plug into

C-25

3400HVFX 208-240

3.7

9

Hardwire

C-85

plug into

or hard-

wire C85

4400VFX

110-120

11.3

40

C-25

plug in

Plug into

C-25

4400HVFX 208-240

5.7

20

Hardwire

C-85

plug into

or hard-

wire C85

8400VFX

208-240

11

40

Hardwire

C-85

plug into

or hard-

wire C85

5.1VFX

208-240

20

97

Hardwire

C-95

hardwire

C95

3 phase

aerators

2.3VFX

208

7.5

40

see your control

panel instructions

5.3VFX

208

16.0

100

2.3HVFX

460

3.6

24

see your control

panel instructions

5.3HVFX

460

7.8

49

VX Pattern Sizes

NOTE: Pattern sizes listed are approximate. Varia-

tions in voltage caused by regional electrical differenc-

es or voltage drop due to long power cords may result
in reduced pattern sizes.

Model

Height

Width

2400VFX

5’

15’

3400VFX

5.5’

21’

3400HVFX

5.5’

21’

4400VFX

8’

26’

4400HVFX

8’

26’

8400VFX / 2.3(H)VFX

8’

32’

5.1VFX / 5.3(H)VFX

10’

34’

important to test the GFI breaker in the control panel

upon each installation/reinstallation of the unit to en-

sure proper functioning.

WARRANTY

Kasco aerators are the result of over 35 years of design

and engineering. Kasco products are built to with-

stand the toughest conditions. Kasco Marine backs

each VFX model aerator with either a 2 Year or 3 Year

Warranty depending on the model. This warranty cov-

ers any and all manufacturers defects within the war-

ranty period from the date of purchase (See Warranty

Section). Please register your aerator online at:

www.kascomarine.com (under the technical tab)

USE AND OPERATION

Kasco aerators are designed and engineered for con-

tinuous duty, such as on fish farms or other aquacul-

ture applications, or on-demand use, as needed in a

recreational water feature.

During flotation operation, the water is pulled from
360

O

around the unit and from below the unit. The

water is pulled upward and thrust through the flotation

collar into the air.

Your Kasco Marine aerator is ready for immediate use

(after installation). Make sure to keep the motor hous-

ing clean from hard water deposits and/or algae. (See

Maintenance Recommendations.)

It is extremely important that proper and sufficient

voltage is supplied to the aerator motor. Unit should

be protected by a GFCI. Control panels must be

installed by a qualified electrician. (See Installation

instructions).

Kasco aerators are lightweight, energy efficient, and

easy to install and operate. We strive to produce prod-

ucts that exceed customer expectations. We hope you

enjoy your Kasco aerator.

UNIT STORAGE

When storing units during the offseason, it is impor-

tant to store them upside down if they are going to be

sitting for long periods of time. Units that sit upright

on a shelf for many months, or even years have a

greater likelihood of seals drying out. Storing upside

down will ensure oil is lubricating the seals and pre-

vent drying.