C-25 timer control instructions – Kasco Marine VFX Series User Manual
Page 11

11
2. If the G.F.C.I. tests okay, restore power by
pushing the RESET button back in. THE RESET BUT-
TON MUST BE PUSHED FIRMLY AND FULLY INTO
PLACE UNTIL IT LOCKS AND RE-MAINS DE-
PRESSED AFTER PRESSURE HAS BEEN REMOVED.
DANGER: IF RESET BUTTON DOES NOT
POP OUT, IF TEST LAMP REMAINS LIT WHEN
RESET BUTTON DOES POP OUT, OR IF THE G.F.C.I.
FAILS TO RESET PROPERLY, DO NOT USE TIMER!
CONTACT A QUALIFIED SERVICE TECHNICIAN!
Failure to use the C-25 with Kasco aerators will void the
warranty and cause the aerator to not be listed to UL and
CSA standards via ETL.
UNDER NO CIRCUMSTANCES SHOULD ANYONE
ENTER THE WATER WHEN A UNIT IS IN OPERA-
TION!
TIMER-OPERATION INSTRUCTIONS
C-25 Control Box will turn the aerator ON & OFF with the
TIMER. Kasco lights will turn ON with the PHOTO EYE
and OFF with TIMER. C-25 Control Box is to be used
with Kasco Approved Lights ONLY!
• Insert “ON” (GREEN) and “OFF” (RED) trippers into
dial at desired ON and OFF times.
• Turn dial clockwise one or more revolutions until
correct time-of-day (AM or PM) in window is aligned
with the arrow.
• Plug aerator cord into the RIGHT hand outlet (labeled
UNIT).
• Plug transformer light cord into LEFT hand outlet
(labeled LIGHT).
FOR TEMPORARY MANUAL OPERATION
Rotate MANUAL knob counter-clockwise to desired ON or
OFF position. Timer will follow next automatic operation.
White connects to Terminal
#7
Green connects to Terminal
G
STEP FOUR:
Test the GFCB with the test button now and every 30
days.
If lights are installed, they can now be installed per Instruc-
tions included with the lights.
Once completed, power can be restored to the panel.
Record the following data while the Aerator is operating
in the water under load:
Voltage:
L1-L2 ________
L1-N _________
L2-N _________
Amperage:
L1 __________
L2 __________
Date installed _____/_____/_____
Any unauthorized modifications to this control panel will
void the UL listing and the Kasco warranty.
C-25 Timer Control Instructions
IMPORTANT
This portable timer is designed for CONTROLLING the
connected equipment only. Unplug timer before servic-
ing the unit or the equipment it controls. THE MANUAL
OVERRIDE KNOB IS NOT TO BE USED AS A POWER
DISCONNECT! For maximum protection against electri-
cal shock hazard, perform test procedure on G.F.C.I. at least
once a month. Mount at least 5 ft. from open water.
G.F.C.I. TEST PROCEDURE
The G.F.C.I. should be checked every month to make sure
that it is operating properly. Just follow the simple instruc-
tions below. It is recommended to maintain a maintenance
diary of your monthly safety check.
1. Push TEST button, RESET button should pop
out from inner surface. This should result in power being
OFF at the outlet protected by the G.F.C.I. Verify by
plugging a test lamp into the outlet. Be sure the timer is in
the ON position.