• Communication Range: >33 ft. (10m)
• Auto Power Off Interval: 15 minutes
• Backlight Fadeout Interval: 90 seconds
• Power Source: (1) “9V” battery
• Power Consumption: <3mA (standby mode);
<20mA (normal operating mode); <25mA (transmitting mode);
<60mA (receiving mode); <80mA (transmit + receive mode)
• Dimensions (Excluding Test Leads):
7.1 x 3.7 x 2.1 in. (180 x 95 x 54mm)
• Weight (Excluding Battery): 1 lb. (450g)
MEASUREMENT RANGES,
RESOLUTIONS & ACCURACIES
AC Voltage (Manual Range)
Range
Resolution
Accuracy
0-400mV
0.1mV
±0.6% of reading ±3 digits
0-4V
0.001V
±0.6% of reading ±3 digits
0-40V
0.01V
±0.6% of reading ±3 digits
0-400V
0.1V
±0.6% of reading ±3 digits
0-750V
1V
±1.0% of reading ±5 digits
DC Voltage (Manual Range)
Range
Resolution
Accuracy
0-400mV
0.1mV
±0.6% of reading ±2 digits
0-4V
0.001V
±0.6% of reading ±2 digits
0-40V
0.01V
±0.6% of reading ±2 digits
0-400V
0.1V
±0.6% of reading ±2 digits
0-1000V
1V
±0.8% of reading ±2 digits
AC Current (uA Setting, Manual Range)
Range
Resolution
Accuracy
0-400uA
0.1uA
±0.15% of reading ±5 digits
0-4mA
1uA
±0.15% of reading ±5 digits
20