Appendix VIII: Remote Functions

Hardware Connections

REMOTE FUNCTIONS

CN14

Remote Zero Switch

3

11 or 12

Remote Print Switch

9

11 or 12

*Dry contacts only.

**Must have I/O accessory installed.

Remote Software Commands using Serial Port/ Mapped Memory/ Multicast

FUNCTION

SOFTWARE COMMAND

Zero Active Scale

Z

Zero ALL Scales

z

Zero a Specific Scale

Z#

where # is the Scale number.

Zero Scales 1-4

ZA

Zero Scales 5-8

ZB

Set Tare on Active Scale

Txxxxx

where xxxxx is the Tare weight value.

Set Tare on a Specific Scale

T#, xxxxx

where # is the Scale number and

xxxxx is the Tare weight value.

AutoTare on Active Scale

A

Change Units on Active Scale

U

Change Units on ALL Scales

u

Change Units on Specific Scale

U#

where # is the Scale number.

Print Active Scale

P

Change to Multi-Screen

m

Change to GTN Screen

g

Select Active Scale

S#

where # is the Scale number.