beautypg.com

Appendix iv: network command functions, Command structure – Fairbanks FB3000 II Operators Manual User Manual

Page 58

background image

02/10

58

51220 Rev. 1

Appendix IV: Network Command Functions

Command Structure:

[Sender],[COMMAND],Command,[End][LF]

Where Sender is:

The Computer Name of the PC which is sending the command.

Where Command is:

Lowercase z =

Zeroes all scales.

Uppercase Z1, Z2, etc = Zero a specific scale.

Uppercase ZA or ZB = Zero Group ScaleA (1 to 4) or Group ScaleB (5 to 8).

Uppercase Txxxxx = Apply Tare xxxxx to Active scale where xxxxx = Tare value.

Uppercase T#,xxxxx = Apply Tare xxxxx to Selected scale # where xxxxx = Tare value

and # = Scale number.

Uppercase A =

Auto Tare Active scale

Lowercase u =

Change units on all scales.

Uppercase U1, U2, etc. = Change units on a specific scale.

Uppercase UA or UB = Change units on Group ScaleA (1 to 4) or Group ScaleB (5 to 8).

Uppercase S# =

Make Scale # (1-8) the Active scale where # = Scale number.

Poll Character (see Configured Output) sends configured output.

LF

= Line

Feed

Example:

[Freds PC],[COMMAND],Z1,[End][LF]

i.e. – Freds PC is requesting Scale 1 to Zero.