beautypg.com

Pillar replacement steps – Fairbanks Aegis Transport Scale User Manual

Page 19

background image

Section 3: Service & Maintenance

04/10

19 51191 Rev. 2

3.2.2. Pillar Replacement Steps

1. Unplug/remove the cable to the Indicator

(or Battery Pack Unit) from the Scale
Platform connection.

2. If it is present, remove the fastening

screws on the battery pack, pulling it
away and setting it aside.

3. Remove all the fastening bolts on the

Indicator Stand, pulling the Indicator
away and setting it aside.

4. At the Wheel-base side of the Platform, remove the

four (4) Fastening Bolts of the Cover using the

seven-sixteenths inch

(

7/16”) Open-ended

Wrench

.

5. Once opened, check the Interface Cable from the

Platform to the Indicator for visible breaks or cracks.

6. Replace the cable, if needed.