3.2.1. Disassembling the Platform

1. Cycle-down the power to the indicator, then unplug the unit, if applicable.

2. Lay down the Scale on its back.

3. At the Wheel-base End of the Platform,

remove the four (4) Fastening Bolts of
the Cover
using the

seven-sixteenths

inch

(7/16”) Open-ended Wrench

.

4. Using a

half inch

(

½”) Open-ended

Wrench

, unscrew the four (4) Bolts

on

each corner of the Platform until each is
past the Load Cell Rubber Foot.

5. Carefully pull up, then out the top edge of

the Scale Platform, and lay it down on the
Pillar.

Be careful not to pinch fingers.

─ Doing this will expose where the Cables

meet at the base of the Indicator Pillar,
and also the Load Cell Connections in
each corner.

6. Check the Interface Cable from the

Platform to the Instrument for visible
breaks or cracks.
While laying down the Platform, pull

out some slack of the wires from the
hole to the Pillar.

C A U T I O N

ALWAYS

remove power from the Instrument before servicing.