beautypg.com

Direct Lift PP9 Plus User Manual

Page 19

background image

19

cal properties, precautionary measures to take, and first aid measures as stated in the Safety Summary before

performing any maintenance with the hydraulic system.

4.

Oil level too low. Oil level should be just under the vent cap port when the lift is down. Relieve all hydrau

lic pressure and add oil as required.

Oil Blows out Breather of Power Unit

If oil blows out of the breather of the power unit, take the following actions:

1.

Oil reservoir overfilled. Relieve all pressure and siphon out hydraulic fluid until at a proper level

2.

Lift lowered too quickly while under a heavy load. Lower the lift slowly under heavy loads.

Motor Hums and Will Not Run

If the motor hums but fails to run, take the following actions:

1.

Lift overloaded. Remove excessive weight from lift

WARNING!!

The voltages used in the lift can cause death or injury to personnel. In the following steps, make sure that a

qualified electrician is used to perform maintenance

2.

Faulty wiring..….... Call electrician

3.

Bad capacitor..….. Call electrician

4.

Low voltage........... Call electrician

Lift Jerks Going Up and Down

1.

If the lift jerks while going up and down, it is usually a sign of air in the hydraulic system. Raise lift all the

way to top and return to floor. Repeat 4-6 times. Do not let this overheat power unit.

Oil Leaks

Oil leak causes at the power unit and cylinders are normally caused by the following:

1.

Power unit: if the power unit leaks hydraulic oil around the tank-mounting flange check the oil level in the