16.3.3. Commands to Set Parameters
Set
Set
Set
Set the
the
the
the Limit/Setpoint Value
Limit/Setpoint Value
Limit/Setpoint Value
Limit/Setpoint Value
Sets the limit or setpoint value of the comparison. The decimal point is not necessary.
Template
Sm,n, [ value ]
m: code memory number, 0 - 4
n : setpoint order number, refer to "Setting the setpoint"
Command
Reply
Set
Set
Set
Set the
the
the
the Zero Band
Zero Band
Zero Band
Zero Band
Sets the F26 value (zero band) of the comparison. The decimal point is not
necessary.
Template
SZ, [ value ]
Command
Reply
Set
Set
Set
Set the
the
the
the Pres
Pres
Pres
Preset Tare
et Tare
et Tare
et Tare
Sets the preset tare value. The decimal point is not necessary.
Template
PT,m, [ value ]
m: code memory number, 0 - 4
Command
Reply
Set
Set
Set
Set the
the
the
the Unit Weight for Counting Mode
Unit Weight for Counting Mode
Unit Weight for Counting Mode
Unit Weight for Counting Mode
Sets the unit weight value with decimal point.
Template
UW,m, [ value ]
m: code memory number, 0 - 4
Command
Reply
16.3. Command Format