External Input
Item
Parameter
Description
** 0
Not used (No function)
1
ZERO key
2
TARE key
3
NET/GROSS key
4
ON/OFF key
5
PRINT key, ENTER key
6
FEED key
7
Serial data output (Format 1)
8
Serial data output (Format 2)
9
Accumulation (M+)
10
Start batching
11
Stop batching
12
“Over” signal, Gross over and display data out when ON
13
NET weight display when shorting the terminal.
14
Accumulated data display when shorting the terminal.
15
Execute comparison when shorting the terminal.
16
Display by the second unit when shorting the terminal.
17
All keys are enabled when shorting the terminal. 
(Ignores F12 setting temporary) 
18
Inhibit memory code reading when shorting the terminal.
19
Start averaging to hold
f13 
EXT1 
Function selection of 
external input 
20
Release holding data
0 to 17, 19 and 20 Same as f13
f14 
EXT2 
18
Code Memory (BCD 1)
0 to 17, 19 and 20 Same as f13
f15 
EXT3 
18
Cord Memory (BCD 2)
*: Initial
settings.
Accumulation
Item
Parameter
Description
10 11 Acc. no (0) / Exec (1)
20 21 Manual (0) / Auto (1)
30 31
+
Only (0) / +/- (1)
f20
[Type2]
Accumulation Mode
40 41 OK only (0) /All data (1)
Left: Sub item, select using the
ZERO
key
Right: Setting, select using the
0
,
1
keys
Initial settings: 10, 21, 31, 41
0
Add data anytime
** 1
Above 5 d
2
Above 10 d
3
Above 20 d
f21 
Inhibit region for 
accumulation 
4
Above 50 d
The selection of the inhibit region 
for accumulation. 
Do not set f21 0 when Auto 
accumulation (f20 21). 
d:
division (weighing interval) of first range.
*:
Initial settings.
6.2.