A&D Weighing Indicator AD-4405 User Manual
Page 29

AD-4405 Weighing Indicator
Page
27
Data Output
Item
Parameter
Description
** 0
No data output
1
Analog output
Set f31, 32, 33
2
Serial output
f30 
Data output 
3
Serial output (Zero suppressing)
RS-232C, 
RS-422/485 
*:
Initial
settings.
 
Analog Output 
Item
Parameter
Description
* 0
Displayed data
1
Gross data
f31 
Output data 
2
Net data
f32 
Weight value at 4mA output 
-999999 to 999999 (Initial setting is 0)
f33 
Weight value at 20mA output
-999999 to 999999 (Initial setting is 
10000) 
Polarity is 
changed by 
pressing the +/- 
key. 
*:
Initial
settings.
 
Serial Data Format 
Item
Parameter
Description
x 0
Terminator
x 1
Device ID (selected at f06)
x 2 Code
number
x 3
Data number *
x 4
Result of comparison
x 5 Date 
x 6 Time 
x 7 Accumulated 
value
x 8 Accumulation
count
x 9
Stable / Over
x a Displayed
weight
x b Gross
weight
x C Net
weight
x d Tare
weight
x e
Weight type (
G /N / T
, refer to Cf06)
f34
[Type3]
Serial data format 1 
 
Initial value 
19, 2e, 3a 4f e50 
 
 
 
f35 
[Type3]
Serial data format 2 
 
Initial value 
17 2f e30 
x f
Weight unit (cf. Cf07)
ZERO
key :
order of output 
 (1-999) 
“Exxx” indicates 
the end of data 
to output 
 
NET/GROSS
key:
Expand or 
shorten output 
data length 
 
0
-
9
,
A
-
F
key
output data 
 
1 The comma of the parameter display indicates that the comma (f46 0, semi-colon
for f46 1) is output after the data. To turn this mark on and off, press the
9
key while
pressing
NET/GROSS
key.
Output of the initial settings of f34(19, 2E, 3A 4F E50) is like “ST,GR,
+12345.6kg”.
2 The data number *(parameter 3) increments automatically with each serial data
output from 1 to 99999 (the next of 99999 is 1). The starting number can be set
using the keys.
6.2.
F-Functions