Series Connections

Series N5700 User’s Guide

33

Local Sensing

Remote Sensing

Refer to the following figure for typical connections of series power
supplies configured as a positive and a negative output.

CAUTION

This caution applies when using analog voltage programming with series-
connected power supplies. The analog programming circuits of these power
supplies are referenced to the negative sense (-S) potential. Therefore, the
analog voltage circuits used to control each series-connected unit must be
separated and floated from each other.

+S

+

-

-S

-LS

+LS

POWER
SUPPLY

+S

+

+

-

-

-S

-LS

+LS

POWER
SUPPLY

LOAD

(*)

(*)

+S

+

-

-S

-LS

+LS

POWER
SUPPLY

+S

+

+

-

-

-S

-LS

+LS

POWER
SUPPLY

LOAD

(*)

(*)

(*) Diodes are
user supplied.

+S

+

-

-S

-LS

+LS

POWER
SUPPLY

+S

+

+

-

-

-S

-LS

+LS

POWER
SUPPLY

(*)

(*)