The Countdown Timer is now set to turn on for 1 hour 10 minutes 30 seconds as
shown in Figure 6. Press the CD key anytime to activate the count down. The display
will show the time counting down when the CD PROG symbol is displayed, until it
reaches zero. When time is up, the timer will turn itself off.
The count down will not start when the random function is active. Regular program is
disabled during the count down period. Activating Random function or Manual On/Off
will cancel the count down operation.
DISABLE/MASTER DISABLE FUNCTION
This function allows you to disable and enable any or all of the 14 preset ON/OFF
programs and CD Program using the ON/OFF key.
To disable a program, display the program or CD Program you wish to disable using
the left/right arrow key, then press the SET key. The display is flashing and the word
SET is lit, press the ON/OFF key to disable the program, the X symbol will appear to
indicate that that particular program is disabled as shown in Figure 7.
Note: The display is still flashing and if there’s no changes to be made on the preset
program, press the SET key until the display is not flashing. Use this function to
disable as many available preset programs as you choose.
The count down will not start when the random function is active. Regular program Is
disabled during the count down period. Activating Random function or Manual On/Off
will cancel the count down operation.
To disable all programs, press the SET key while in clock display. Then press the
ON/OFF key to disable all the preset programs when the display is flashing, The
Xsymbol will appear on the clock display Indicating that all preset programs are
disabled.
Please note that CD Program will not be affected by the master disable.
To cancel the disable function, just repeat the same procedure to turn off the X
symbol.
AUTO-RETURN TO CLOCK DISPLAY
If the unit is left idling more than 1 minute during programming or displaying another
mode, the display will return to clock and the programming operation Is cancelled.
However, if the display is showing count down time in progress, auto-return will not
activate, until count-down is finished.
SUMMER/WINTER TIME
Press both the UP and DOWN ( < and > ) keys at the same time to change the current
time to SUMMER time mode. The current time will be advanced by one hour and the
symbol of SUN will light up to denote that the summer mode is activated. To shift the
time mode back to normal press both the UP and DOWN ( < and > ) keys at the same
time once again.
RESET
Use a round object such as a ball-point pen to push the reset key while the SET key is
pressed. Then release the RESET key first before the SET key. After reset, all preset
programs are erased from timers memories.
ABNORMAL DISPLAY
When an abnormal display or a blank display appears on the timer, use the above
Reset procedure, otherwise the timer may not work properly. Be sure that the
rechargeable battery is adequately charged.
BATTERY REPLACEMENT
Before operating, two 1.5V type LR44, A76, V13GA or RW82 button cell batteries
should be installed into the unit. This can be done by removing the battery
compartment at the back of the unit, and placing the battery into the compartment
while observing the correct polarity as shown on the battery compartment. Then place
the compartment back into the unit. The battery serves to back up the reading and
programs should there be a power failure or when the unit is unplug from their outlet.
Note: If you plan to leave the unit unplugged for a long period of time (more than 12
hours), the battery should be removed in order to conserve battery consumption. And,
when you need to replace new battery back to the unit, unplug the unit from the outlet
first before installing battery.
Warranty, Service, or Recalibration
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714 Fax 281-482-9448
E-mail [email protected]
www.control3.com
Control Company is ISO 9001 Quality-
Certified by DNV and ISO 17025 accredited
as a Calibration Laboratory by A2LA.
Control Company Cat. No. 92-5050-00 Rev. 2 051908
Traceable
®
is a registered trademark of Control Company
© 2008 Control Company