5.
If a pause in the countdown or countup timing operation is required press
the START/STOP button to “freeze” the display at the current reading
(time-out). To resume time at the point it was stopped, press the
START/STOP button again. An unlimited number of timeouts may be
taken.
Cumulative and Lap/Split
Cumulative split time measures partial times while the stopwatch continues to
measure total elapsed time. Lap/Split time measures each round of timing
(noncumulative).
1. Timing operation
i.
Hold the RESET button for 2 seconds, a beep will sound and all 3 lines on
display will reset to zero.
ii.
Press the START/STOP button to start timing. The bottom line on display
will begin timer operation.
iii.
Press the LAP/SPLIT button to record Lap 1 on the stopwatch. (001) will
display at the upper left of the screen. The cumulative time will show on the
top line of the display. The time length of Lap 1 will show on the middle line
of the display. The bottom line of the display will continue normal timing
operations.
iv.
Each press of the LAP/SPLIT button will record and display the next
succession of laps. A total of 300 lap/split times can be entered into the
stopwatch memory.
v.
Press the START/STOP button when the timing event is completed.
2. Lap/Split Memory Function
After the timer has been stopped and the event is complete, various memory
functions can be recalled.
i.
Press the RECALL button, the word RECALL will appear under the lap
counter at the upper left of the display.
ii.
With each press of the RECALL button various stored data will be
displayed and the data information named under the timer counter.
iii.
The various memory functions are listed below in the sequence they
appear:
Fastest Timed Lap - FAST appears under the lap counter, the number of the
fastest lap appears in the counter, the lap time shows on the middle line of
display and the top line shows the cumulative time of the lap.
Slowest Timed Lap - SLOW appears under the lap counter, and as stated above,
the display shows the recorded time of the slowest lap – lap number, lap time
and cumulative time.
Averaged Timed Lap - AVG appears under the lap counter, the lap counter will
display the number of laps recorded in the Recorded Lap/Split Times.
Recorded Lap/Split Times –(001), (002), etc.
Each lap time data will be shown in the order in which they were recorded. The
lap counter will show the lap number, top line displays the cumulative time and
the middle line shows the lap time.
3. To clear the memory press the MODE button, Recall will no longer be
displayed, then press RESET.
Speed Mode
1.
Press the MODE button to advance the display to the speed mode.
NOTE: The unit is “per hour” therefore speed = set distance x 3600
seconds. The maximum display of speed is 9999.999, if any calculated
speed is over this value, Error will show in the middle row and speed value
will not be stored into memory.
2.
Press and hold the RECALL button for 2 seconds until Km is flashing.
3.
Press the RESET button to move to the top line of the display, which is
distance. Continuing to press moves the blinking digit.
4.
Press the START/STOP button to advance digits to the correct distance.
Press RECALL to confirm the entry.
5.
Press the START/STOP to begin timing.
6.
Press the LAPSPLIT for the laps.
7.
Recalling memory in speed mode:
i.
When the stopwatch is stopped; the following will show with each
press of the RECALL button. (top row = LAP, middle row = SPEED,
bottom row = TOTAL TIME). Fastest speed/lap, slowest speed/lap,
average speed/lap and then each speed/lap stored in memory.
ii.
When the stopwatch is running; the same is displayed except that the
time continues to run on the bottom row.
Stroke/Frequency Measuring Mode
This mode calculates frequency by taking 3 strokes (cycles) within a time period
and then calculating the expected number of cycles if that action is continued for
1 minute.
1.
Press MODE button to show the Stroke /Frequency Measuring Display.
2.
Start the measurement by pressing the START/ STOP button. Then press
the START/STOP button after the third stroke is made. The number of
strokes per minute will be displayed on the lower row, while the
measurement time will show on the upper row.
NOTES
1.
Pressing the START/STOP button faster than 1/8 second (0.125 sec) will
cause an Error to display indicating the overflow of the showable value.
2.
Pressing the START/STOP button longer than 18 seconds will cause an
Error to display which indicates the time period is too long.
3.
Pressing the RESET button while the measurement is stopped or while an
Error is shown, causes the digits to be reset to 2400.
ALL OPERATIONAL DIFFICULTIES
If this unit does not function properly for any reason, replace the battery with a
new high-quality battery (see “Battery Replacement” section). Low battery power
can occasionally cause any number of “apparent” operational difficulties.
Replacing the battery with a new fresh battery will solve most difficulties.
BATTERY REPLACEMENT
An indication that the battery must be replaced would be erratic readings, a faint
display, no display, or if all icons/digits of the display are highlighted. Remove the
screws on the back of the unit and remove the back cover. Remove the screw
holding the battery bracket in place. Remove the exhausted battery and replace
with a new battery. Secure the battery bracket into place, replace the back of the
unit and replace and tighten screws. Replacement battery Cat. No. 1005
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road •
Friendswood, Texas 77546 • USA
Ph. 281 482-1714 •
Fax 281 482-9448
www.control3.com • [email protected]
Control Company is ISO 9001 Quality-
Certified by DNV and ISO 17025
accredited as a Calibration Laboratory
by A2LA.
Traceable
®
is a registered trademark of Control Company
© 2007 Control Company
92-1052-00 Rev. 3 122707