beautypg.com

Control Company 5017 FLASHING LED ALERT BIG-DIGIT DUAL CHANNEL ALARM TIMER User Manual

Page 2

background image

While a channel is alarming, once the channel is

selected by pressing the T1 / T2 button, pressing

the S/S button will stop the alarm, stop the count-up

timing, and recall the programmed countdown time.

After one minute, pressing the S/S button for the

selected channel will stop the count-up timing. To

recall the programmed time, press the M button.
Both timing channels may be used simultaneously.

cLeaRinG coUntDown MeMoRY

1. Select the desired channel by pressing the T1 / T2

button.

2. Clear the display to zero.

3. Press and hold the M (memory) button for three (3)

seconds (the display will flash zero).

4. With the display flashing zero, press the M

(memory) button to confirm the entry (the display

will no longer flash).
StopwatcH (coUnt-Up) tiMinG

1. Select the desired channel by pressing the T1 / T2

button.

2. Clear the display to zero.

3. Press the S/S button to begin count-up timing.

4. Press the S/S button to stop count-up timing.

Once timing is complete and the timer has

been stopped, press the HR and MIN buttons

simultaneously to clear the display to zero.
Both timing channels may be used simultaneously for

countdown or count-up timing.

tiMeoUt

A timing channel may be stopped during any running

time (countdown or count-up) by selecting the channel

and pressing the S/S button. Timing may be resumed

by pressing the S/S button a second time.

conVeRt a tiMeoUt to a coUntDown tiMe

A timing channel may be stopped during any running

time (countdown or count-up) by selecting the channel

and pressing the S/S button. Once the timing has

been stopped, pressing the HR, MIN and SEC buttons

will increment the display from the point that it was

stopped and will set the timer into countdown mode.

Once the desired time is on the display, press the S/S

button to begin countdown timing.

aLL opeRationaL DifficULtieS

If this timer does not function properly for any reason,

replace the batteries with new high quality batteries

(see the “Battery Replacement” section). Low

battery power can occasionally cause any number

of “apparent” operational difficulties. Replacing the

batteries with new fresh batteries will solve most

difficulties.

BatteRY RepLaceMent

An incorrect display, no display or operational difficulties

indicate that the batteries should be replaced. Slide

open the battery cover on the back of the timer. Insert

two (2) new AAA alkaline batteries. Make certain to

note the proper polarity as indicated by the diagram in

the battery compartment. Replace the battery cover.

waRRantY, SeRVice, oR caLiBRation

For warranty, service, or calibration contact:

Control Company

4455 Rex Road

Friendswood, Texas 77546 USA

Ph. 281 482-1714 • Fax 281 482-9448

www.control3.com • [email protected]

Control Company is ISO 9001 Quality-Certified by DNV and

ISO 17025 accredited as a Calibration Laboratory by A2LA

Control Company Cat. No. 5017

Traceable

®

is a registered trademark of

Control Company.

©

2010

Control Company.

92-5017-00 Rev. 1 093010

traCEaBlE

FlaSHInG

lED alErt

BIG-DIGIt

DUal CHannEl

alarm tImEr

InStrUCtIonS

®