Accessories, Specifications – Nova-Tech pH 310 User Manual
Page 23

45
44
13. Accessories
Replacement meters
35618-02 Replacement waterproof pH 300 meter
35618-70 W
aterproof pH 300 meter kit.
Includes “All-in-One” pr
obe, five each of pH
“Singles” buf
fer pouches pH 4.01; 7.00; 10.01; and rinse water
, one squeeze bottle for
deionized rinse water
, batteries, instr
uctions and two electr
ode brackets,
all in a har
d shell carrying case
35618-12 Replacement pH 310 meter
35618-72 W
aterproof pH 310 meter kit.
Includes “All-in-One” pr
obe, five each of pH
“Singles” buf
fer pouches pH 4.01; 7.00; 10.01; and rinse water
, one squeeze bottle for
deionized rinse water
, batteries, instr
uctions and two electr
ode brackets, all in a har
d
shell carrying case
Electrodes and probes
35618-05 T
emperature probe.
For pH 300 and pH 310 meters
35808-71 Replacement “All-in-One” combination pH/temperature probe
,
single junction, sealed, 145 mm L
x
12 mm diameter (0.5 lb)
35801-00 pH electrode,
epoxy body
, single-junction,
145 mm L
x
12 mm diameter (0.5 lb)
35805-13 ORP electrode,
epoxy body
, single-junction,
145 mm L
x
12 mm diameter (0.5 lb)
00653-04 Electrode storage solution,
1 pint bottle. Keeps electr
ode bulb moist for
faster
, mor
e accurate r
eadings. (1.1 lbs)
00653-06 Electrode cleaning solution,
1 pint bottle. Removes buildup fr
om
electr
odes and maintains electr
ode sensitivity
. (1.1 lbs)
NOTE: Remember to check the temperatur
e calibration when r
eplacing the
A
T
C
pr
obe or when using with an OAKT
ON
®
"All-in-One" combined pH and
temperatur
e pr
obe. See section 4.5, "T
emperatur
e calibration" (page 17).
Continued on next page
12. Specifications
Mode
pH
T
emperature
mV
–10.0 to 1
10.0˚C
-2000 to 2000 mV
Range
-2.00 to 16.00 pH
(also 14.0 to 230.0°F
(same for Rel mV)
for pH 310 meter)
Resolution
0.01 pH
0.1˚C (also 0.1°F
0.1 mV between ±
199.9 mV
for pH 310 meter)
1 mV beyond ±
199.9 mV
Accuracy
±
0.01 pH
±
0.5˚C (also ±
0.5˚F
±
0.2 mV between ±
199.9 mV
for pH 310 meter)
±
2 mV beyond ±
199.9 mV
Input
BNC
connector
6-pin plug
BNC
connector
Calibration
pH 300 meter:
Up to five points (pH1.68, 4.01, 7.00, 10.01, 12.45)
pH 310 meter:
Up to six points—select fr
om thr
ee dif
fer
ent buf
fer sets:
USA
buf
fers (pH 1.68, 4.01, 7.00, 10.01, 12.45)
NIST buf
fers (pH 1.68, 4.01, 6.86, 9.18, 12.45)
DIN buf
fers (pH 1.09, 3.06, 4.65, 6.79, 9.23, 12.75)
T
emperature:
Of
fset in 0.1°C incr
ements
mV
:
Of
fset up to ±
150 mV
Memory:
pH 300 meter:
up to 16 data sets (pH or mV plus temperatur
e)
pH 310 meter:
up to 50 data sets (pH or mV plus temperatur
e, date, and time)
pH slope range:
80% to 1
10%
T
emperature compensation:
automatic (A
TC) or manual fr
om 0 to 100°C
Operating temperature:
0 to 50°C
Power:
four 1.5 V
AAA
batteries (included)
Battery life:
> 100 hours
Housing:
meets IP67 standar
ds for waterpr
oof and dustpr
oof housing
Di
mensions:
Meter: 7.5"L
x 3.5"W x 1.75"H
(19.1 cm x 8.9 cm x 4.5 cm)
Boxed: 9.2"L
x 8.5"W x 2.75"H
(23.3 cm x 21.6 cm x 7 cm)
Shipping weight:
1.3 lbs (0.6 kg)
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(86
6) 433-6682