0 specifications – Nova-Tech AE402 Indicator User Manual
Page 5
3 |
P a g e
© Adam Equipment Company 2010
2.0 SPECIFICATIONS
External resolution ratio
1/1000-1/30000
Non-linear error
±0.016% F.S
Range of signal input of
the transducer
0-20mV
Load cell drive capacity
up to 4, 350Ω or 1000Ω load cells
Load cell excitation
+ 5V DC
Load Cell Connection
6 wire connection, 2 x excitation, 2 x sense, 2 x signal
plus shield.
Calibration
Automatic External
Stabilisation Time
2 seconds typical
Power supply
6V 4Ah Rechargeable battery And
AC/DC 12V 800mA adapter power;
Power consumption
0.1VA
Overall dimension
240 x 140 x 104 mm (including bracket)
Balance Housing
Indicator: IP 65 rated Stainless Steel
Net weight
2 kg
Operating temperature
0C-40C
Operating humidity
≤85% RH
Applications
General Purpose Weighing Scales
Functions
Weighing, Check weighing, Parts counting, Memory
Accumulation, Animal weighing, Percent weighing
Display
6 digits, 40mm digit height LCD digital display with
backlight
Weighing units
Grams, Kilogram, pound, ounce, pound/ounce; Newton;
Symbol indication
battery; stable; net weight; zero set; Animal Weighing;
Hold
Interface
RS-232 bi-directional Interface