Electric schematic – Diamond Products CC4130E-XL User Manual
Page 6

AGC
FUSE
DIAGRAMS
TO FRAME
6045491
DO NOT GROUND
TRANSMISSION
PICKUP AT
TO MAG
TACH/
HOUR
SEE CONNECTION
METER
460V CONNECTION
SHOWN 500VA
2800072, BLACK
6048092, BLACK
10
2L3
L1 L2 L3
DISC1
OFF
ON
(+)
(-)
1L3
MTR AMMETER
AMR1
M1
MTR1
H.P.
FU1
4A (ATQR)
T1
3
25A
3A
CR2
X1
STOP
PB1
FU3
2
M1
6
2
MOTOR STARTER M1
X1
AC2
AC1 BR1
CRYDOM
10
?
METER
AM1
(GRN-SJO)
9
11
(RED-SJO)
RAISE
PB3
BAT 12 VDC
CR2
(ORG-SJO)
(BLK-SJO)
LOWER
PB4
LT1
OFF
ON
HYDRAULIC LIFT MOTOR
HYDRAULIC PUMP RELAY
UP INTERLOCK RELAY-REMOTE (CR2)
LOWERING SOLENOID
SPOT LIGHT OPTION, 6011490
[OPTIONAL]
2L3
2L1
5
4
AGC
(+)
13
10
10
1
2
9
9
14
1L2
1L1
FU2
10A
M1
OL1
START
PB2
(-)
(BLUE-SJO)
CR2
1L1
3L2
5L3
2T1
4T2
6T3
5s
10
20
0s
20s
0s
Max
Min
"ON" Ramp Time (20s)
Initial Torque
"OFF" Ramp Time (0s)
A2 A1 1
TO A
5
SOL
P
HLM
25-100A
SOFT START
M1
(GREEN 14 GA.)
P
120V AC
25.2V AC
FROM A
X1 X2 X3 X4
H1 H2 H3 H4
H1 H2 H3 H4
OL
* T1
* T1
T2
2 (14GA WHITE)
(ATQ
R)
(ATMR)
10GA (RED)
10GA (WHITE)
14GA (RED)
OFF
ON
WP
FUSE
WATER PUMP OPTION, 6011348
T1
X1
2
X2 X3
X1
X4
H1
H2
230V
T3
[OPTIONAL]
575V
3
AGC
* 230/460V STANDARD
* 575V SPECIAL OPTION
2L1
DC CHARGING
FUSE
Secondary Voltage Connection
25.2V
6011502 WIRING SCHEMATIC, 4130E
Primary Voltage Connections
230V
460V
12.6V
12.6V
8 7 6 5
4 3 2 1
2800071, RED
6