beautypg.com

Detroit Radiant Products Company LD3 Series User Manual

Page 49

background image

49

LD3

Series

Figure 4.1

Operational Indicator Lights

Light 3

Indicates High Fire

Operation

Light 1

Indicates Pressure

Switch Closes

Operational Indicator Lights

4.0

Operation

Diagnostics

Light 2

Indicates Low Fire

Operation

Chart 4.1 •

LED Diagnostic Codes - Capable Controls Board

Chart 4.2 •

LED Diagnostic Codes - Fenwal Circuit Board

LED CODE

FAULT STATUS

FAULT CODE DELAY*

Initial flash (Red) on power up

Normal operation

Immediate

Steady flash (Green) during Ignition

Normal operation

Immediate

Steady on (Green) after flame sense.

Normal operation

1 minute

1 flash (Red)

Ignition failure

3 minutes

2 flashes (Red)

Ignitor error

12 seconds

3 flashes (Red)

Gas valve error

4 flashes (Red)

Line voltage frq. error

5 flashes (Red)

Internal control error

6 flashes (Red)

Pressure switch error

*Some LED codes have a time delay before the LED will flash.

*Some LED codes have a time delay before the LED will flash.

LED CODE

FAULT STATUS

FAULT CODE DELAY*

Initial flash on power up,

then steady off

Normal operation

Immediate

Steady on

Module failure/Internal fault

Immediate

1 flash

Ignition failure

32 minutes

2 flashes

APS 1 failure

12 minutes

3 flashes

APS 2 failure

22 minutes

4 flashes

Solenoid valve fault/Leaky
valve/Flame amplifier fault

Immediate

No flash on 117V start-up

Transformer fault

Immediate