MP Pumps HTO 120 INSTALL User Manual
Form 3061-b, Mp pumps hto series, Hto 120 installation and service instructions
FORM 3061-B
PRINTED IN U.S.A. (1-07)
MP PUMPS HTO SERIES
This bulletin must be read completely before installing, operating, or servicing the pump.
HTO 120 INSTALLATION AND SERVICE INSTRUCTIONS
WARNING:
If any of the items listed below are violated, serious injury or death from burns caused
by hot oil may occur.
• DO NOT perform service or maintenance when
the pumping system is pressurized or hot -
serious injury or death from burns caused by hot
oil may occur.
• DO NOT operate the pump in a manner that it
was not intended to be use.
• DO NOT install for use in an open environment
where people are present.
• DO NOT install in a rigid piping system that
does not allow the pipe to expand and cause the
pump to be strained.
• DO NOT continue to operate the pumping
system when a known leak exists or the system
continues to smoke.
• DO NOT continue to operate the pump when
unusual noise or vibration occurs.
• DO NOT install or use near water where the
pumping system may come into contact with
water or is splashed by water.
• DO NOT operate beyond the pressure or
temperature limits stated in the product
literature, see form 9050.
• DO NOT allow severe temperature
changes to occur in a short time period
within the pumping system.
• DO NOT mix different types or grades of oil
within the oil system.
• DO NOT use an oil that is not a
recommended heat transfer oil by the
manufacturer.
• DO NOT exceed the maximum oil
temperature rated by the oil manufacturer
at the hottest point in the pumping system.
• DO NOT mount the pump such that high
piping loads exist on the pump flanges.