ANNUAL MAINTENANCE CHECKLIST:

PART

PROCEDURE

Air Filter (“Water Trap”)

Drain. Repair any leaks or damage.

Gauges and Regulators

Check for damage and proper operation.

Accumulator

Remove and clean inside. Replace the O-Rings.
Danger: Never attempt to remove an accumulator
until you have relieved pressure.
See Chapter 6
Accumulator & Filter.

Fluid Section

Replace the oil in the oil reservoir. Clean and dry the
silencers. Check piston rod, trip sleeve, cylinder head
and piston for wear or damage, replace as required.
Replace the O-Rings, piston cups and packing set.
Rebuild lower assembly.