SIX MONTH MAINTENANCE CHECKLIST:
PART
PROCEDURE
Air Filter (“Water Trap”)
Drain.
Hoses
Check for kinks or leaks.
Gauges and Regulators
Check for damage and proper operation.
Accumulator
Remove and clean inside. Replace the O-Rings.
Danger: Never attempt to remove an accumulator
until you have relieved pressure. See Chapter 6:
Accumulator & Filter.
Fluid Section
Replace the oil in the oil reservoir. If necessary, clean
and dry the silencers. Check piston rod, cylinder head,
piston and trip sleeve for wear and damage, replace as
needed. Replace O-Rings, cups, and packing set.
Check the pickup hose and wand for leaks and
damage. Check for packing leaks. Check piston rod
and pump cylinder for wear, replace as needed.
Replace the packing set, piston cups and O-Rings.
Catalyst Jug
Check and clean tubes and filter screens if necessary.
Danger: Fire and explosion hazard. Never allow
solvent or grease to contact any part of the catalyst
system.
Air Lines
Check for leaks, wear and kinks. Replace if necessary.
Catalyst Pump
Replace all soft parts of the catalyst pump. Be sure to:
check bushings and pump cylinder and replace S.S.
balls, O-Rings, springs, piston seal and packing set.