beautypg.com

Requirements, Air requirements, Tool and supplies requirements – Magnum Venus Plastech UltraMAX HVLS-1000 Series User Manual

Page 17

background image

HVLS-1000 Series Fluid Section Manual

Rev. 05/2012

Page | 17

Requirements:

Air Requirements:

Clean, dry compressed air must be available at up to 90 psi (6.3 kg/cm

2

) and a minimum volume

of 14 CFM (0.4 m

3

). Air must be provided through an air hose with a diameter of 0.5 inch (1.3

cm) or greater.

Tool and Supplies Requirements:

When performing service and repair on the Fluid Section, you should have the following tools,
spare parts and supplies available before beginning.

NOTE: Items followed by a * may be purchased from Magnum Venus Plastech.

One table vise

Loctite™ 243 (removable) or equivalent thread lock compound

One small hammer

Needle-nose pliers

Solvent or emulsifier for cleaning

One clean work table

Set of hex wrenches * (08469)

One 5/8-inch wrench * (08474)

One 9/16-inch wrench * (08476)

One 5/16-inch wrench * (08477)

Empty buckets for cleaning

Clean ¼-inch plastic dowel or rod

One 8-inch adjustable wrench * (08467)

One 12-inch adjustable wrench * (08468)

One 7/16-inch open-end wrench

One ½-inch socket wrench

One 7/16-inch socket wrench * (08472)

Wooden sticks or tongue depressors (for testing)

Labels and pens (for marking pneumatic lines)

Clean rags and paint brushes for cleaning equipment

One tube of medium-weight lithium grease (such as Lubriplate

®

lubricant * (08465))

Large (approximately 3 feet by 10 feet or 1 meter by 3 meters) strips of paper for
performing spray tests.

One pin wrench * (45031-1) (comes with catalyst jug)

One scribe * (08126)

Red Grease * (6706-2-1 1oz can) (6706-2-16 16oz can) (6706-2-32 32oz can)

Seal Kit * -

HVLS-1000-SK

Seal Kit – High Volume Fluid Section

HVLS-10SK-4U-1T

Seal Kit – four HVLS-1010-U Packings