IT400 Remote Totalizer & Rate Indicator

Page: 3

DOC#: MN-IT400-R2d.doc

Specifications

Display

Total

8 digit 5.40mm high LCD (continuous display)

Batch total (magnetic reset)

Grand total (no reset)

Rate

5 digit 8.66mm high LCD (continuous display)

Range over/under limit indication

Refresh rate: Multiple depending on power
mode (1/16s, 1/8s, 1/4s, 1s, 0.5s)

Backlighted green w/ LED (magnetically activated
and timed)

Dual segment low-battery warning

Maintenance due warning

Temperature range warning

Power:

Internal: D Lithium battery

Battery life: Various: typical per power mode:
1: 1yr, 2: 1yr; 3: 3.6yr; 4: 3yr; 5: 8yr

External DC: 5 to 48VDC +/- 2 VDC reverse
polarity protected (Max: 12mA w/ backlight)

Loop: requires 7VDC of loop supply

Loop powered from the 4-20mA loop input
(non-isolated)

K-Factor range

Pulses per gallon: 0.0000001 to 999999

Signal Input (flow)

Frequency: 0-3000Hz

Impedance: 10k ohms

Magnetic

Sensitivity: 50mV-36V (field adjustable) sine
or square wave

Modulated carrier

Carrier frequency 50kHz (requires external
power or loop power)

Compensation Input

Temperature - RTD

Two wire 10k ohm

Coefficient of Thermal Expansion method

Frequency

Linearization table 2 to 20 points

Engineering Unit Conversions

Pre-programmed units: Gallons, Liters, Ft

3

, M

3

,

Pounds, BBL, KG (custom weight available)

Custom units available with given units/gallon

Rate and Total may have separate unit displays

Decimal Locations

Total: Two places (and x10, x100)

Rate: Three places (and x10, x100), autorange

Time Base

Rates can be displayed in units per second,
minute, hour, day, and custom (in seconds)

Outputs

Factored Pulse (Max: 150mA, 30VDC, 150mW)

Opto-isolated open collector output

Frequency or fixed pulse width (1, 2, 5, 10,
50, 100, & custom ms) output setting

Output pulse Divider: 1, 2, 5, 10, 50, 100,
1000, & custom

Alarm (Max: 150mA, 30VDC, 150mW)

Programmable opto-isolated open collector
output

Can be used to control totalization

(Max values at 25°C. Max combined Pulse/Alarm
output power: 190mW @ 25°C, 32mW @) 65°C)

Rate (4-20mA)

Factored rate to current loop output

Programmable low and high

Fully isolated (unless loop powered)

Loop Voltage limit: 7-36VDC

Accuracy

Display: ±0.01% reading (rate) or ± 1 count (total)

Analog output: ±0.025% of fs @20°C

Digital output: ±1 count

Environmental

Operating: -30 to 65°C (-22 to 150°F)

Storage: -40 to 85°C (-40 to 185°F)

Enclosure

Explosion Proof Aluminum

FM Approved, CSA Certified

Class I, Division1, Groups B, C, & D

Class II, Division 1, Groups E, F, & G

NEMA 4X, IP66

All openings ¾” FNPT

Weight: 2.5lbs.

Mount: Directly on flowmeter or Wall mount

Compliance

CE 0575

ATEX Ex II 2 G Ex d IIC T6 Gb (X and WX
enclosure types only)

DNV-2008-OSL-ATEX-19241X

Communications

RS-232

Datalogger

Up to four triggers (including timer)

Up to seven system values

Real-time clock

RS-232 or Internal SD/MMC Flash media card

Other features

EEPROM setup storage (>100 year retention)

All features/settings are field programmable.
Convenient number input via 0-9 rotary switch and
two pushbuttons