beautypg.com

Li ner, Table, Fy 01 – Liquid Controls Sponsler IT400 Electronic Register User Manual

Page 31: Fac01, Uni tt, Fct or, Dec t

background image

Liquid Controls
Sponsler, Inc.

IT400 Remote Totalizer & Rate Indicator

Page: 28

DOC#: MN-IT400-R2d.doc

3. Linear

Interpolation

4. K-Factor

5. Totalizer

Units

6. Totalizer

Decimal Place

DI SABLED

LI NER

ENABLED

LI NER

Feature 'L'

Purchased?

Yes

EDI T No

TABLE

EDI T YES

TABLE

*10

.000000

FY 01

Number

Entry

*5

.0000000

FAC01

Number

Entry

No

Repeat at

most 20

times

- - EXI T- -

FAC01

Last Point

-OR-

FY = 0?

No

Note: Set FY to zero
after last valid entry

Yes

1

.0000000

UNI TT

60

.000000

FCt or

Set with

Dial*

Number

Entry

DEC T

Set with

Dial*

Linearizer

Enabled?

No

Yes

8

.3359000 LBS

3

.7810000 KG

1

.2000000 (Custom)

Select

Digit

*GAL, LIT, LBS, FT3, M3, BBL, KG, Custom

*0.01, 0.1, 0, x10, x100

Menu

Enter

Menu

Enter

Select

Digit

Menu

Enter

Menu

Enter

Menu

Enter

Menu

Enter

Menu

Enter

Select

Digit

Select

Digit

Select

Digit

Select

Digit

Select

Digit

Menu

Enter

Menu

Enter

Menu

Enter

Menu

Enter

Select

Digit

Number

Entry

P2-1

P3-1

* Actual readings will vary

**To Exit: Hold

Menu

first, then

press

Select

, then release

Menu

**

**