PUlse oUTPUT devICe (Pod)

Pulse Output

Device (POD)

Port

LectroCount LCR-II

Gallons

GND (37)

CHB (34) CHA (33)

+V

o (31)

POD Pulser

Meter System with Pulse Output Device

Pulse output device (Pod)

Installation

When ordered as part of a meter system with a LCR-

II, Liquid Control’s Pulse Output Device (POD) is

installed onto the meter and wired to the LCR-II at the

factory. The POD can also be ordered separately and

installed onto meter systems already in service. For

mechanical installation instructions, refer to the POD

manual. Instructions for wiring the POD to the LCR-II are

provided on this page.

Materials needed for wiring valves:

not supplied

with the Pod

22 AWG stranded wire (4)

Weatherproof flexible conduit, ½" diameter and ½" NPT

conduit connectors or cable glands

PTFE tape or pipe sealant

To wire a Pod to the lCr-II:

1. Attach cable glands and/or conduit connectors to the

POD and the LCR-II port(s).

2. Thread the wires through a piece of weatherproof conduit

cut-to-length from the POD port to a LCR-II port.

3. Run the weatherproof conduit between the POD and

the LCR-II housing, pull the wires through the ports, and

tighten the connectors.

4. Connect the four POD terminals to four terminals on the

j18 terminal block of the LCR-II CPU board.

• POD terminal 20 to LCR-II terminal 31

• POD terminal 21 to LCR-II terminal 34

• POD terminal 22 to LCR-II terminal 33

• POD terminal 23 to LCR-II terminal 37

single Channel Pulse Inputs

The LCR-II is compatible with the many single channel

pulsers and amplifiers, for example, the SP714 pulse

amplifier. For the LCR-II to accept a single channel

pulse, you will need version v1.15 (or above) of the

SR260 base software and a jumper.

To a single channel pulse output to the lCr-II

1. Flash the CPU board with version v1.15 (or higher)

SR260 base software.

2. Slide the jumper onto the bottom two pins of j17. The

jumper fits over the pins and under the plastic casing.

3. Wire the single channel pulser to the j8 terminal of the

board. Schematic on the right shows wiring to a Sponsler SP714.

Disconnect the power before working on the CPU board.

Disconnect Power

This wiring schematic applies to pulse output devices 1

through 4 only.