valves

A2847-11 Solenoid-Operated

Block Valve

Single Stage (S1) Block Valve

S1 Solenoid

LectroCount LCR-II

Gallons

Electro-Pnuematic

Preset Valve

Single Stage Electro-Pnuematic

Valve with V-7 Valve

S1 Solenoid

V-7 Valve

Electro-Pnuematic

Actuator

LectroCount LCR-II

Gallons

A2859-11 Block Valve

and 3-Way Solenoid

Single Stage

3-Way Valve

single stage systems

liquid Controls’ valves overview

When ordered as part of a meter system with a LCR-II,

Liquid Control’s control valves are bolted onto the meter

and wired to the LCR-II at the factory. Electronic control

valves can also be ordered separately and retrofit onto

meter systems already in service. These valves will need

to be piped and wired in the field. For piping instructions,

refer to the valve manual. This manual includes wiring

instructions for the valves.

In order to control flow, the LCR-II energizes and de-

energizes solenoid-operated valves on external bypass

piping routed off the main product flow. The solenoid

operated valves close off and open the bypass pipes.

The bypass pipes redirect some of the product flow

in order to open and close the control valve. These

solenoid-operated valves must be wired to the LCR-II

CPU board during installation.

Liquid Controls offers single stage and two stage

electronic valves. Single stage valves have one solenoid

valve (S1) and two positions—an open position and a

closed position. Two stage valves have two solenoid

valves (S1 & S2) and three positions—open, closed, and

dwell flow. Dwell flow is a low flow rate setting controlled

by the S2 solenoid and initiated shortly before the

register reaches a preset value.

sInGle sTaGe valves

The three most common Liquid Controls meter systems

with single stage valves include a block valve with a

S1 solenoid-operated valve fitted onto external piping

(A2847-11), a block valve (A2843) with a 3-way solenoid,

and an electro-pnuematic valve with an S1 solenoid.

A2847-11 Valve

This single stage control valve has a S1 solenoid-

operated valve located at the meeting point of three

external pipes: one pipe from the inlet side of the valve,

one from the top of the block valve, and one from the

outlet side of the valve. This valve is typically used in

refined fuels applications.

A2843 Valve and 3-Way Solenoid

The 3-way solenoid-operated valve—mounted directly

to the top center port on the back of the LectroCount

LCR-II—serves as a S1 solenoid-operated valve. The

3-way solenoid-operated valve is located at the meeting

point of two pipes from the vapor eliminator (one for

eliminated vapor and one leading to the spit tank) and

one pipe to the top of the block valve. 3-way solenoid-

operated valves are typically specified for products that

hold vapor in the line such as LPG and NH

3

.

The LCR-II is also compatible with many other brands

and types of valves.