TyPICal adjUsTable TrUCK seaTs & GroUnd CheCK

Checking for a Good Ground

After installing the ground kits, use a multimeter to confirm that the seat and printer are both grounded properly.

To check for a good ground connection:

1. Turn OFF all accessories, including the dome light, to prevent other currents from distorting the reading.
2. Take a multimeter and measure the resistance between the brackets the two ground strap bolts are fastened to. Find a clean

spot on the brackets without paint to use as contact points. Other bolts on the brackets are often suitable.

2a. If the resistance is less than 3Ω, the system is grounded adequately.
2b. If the resistance is still greater than 3Ω, check for proper metal to metal

contact on both ends of the ground strap. Clean any paint, dirt, or oxidation

that may block the grounding point. If the resistance remains above 3Ω,

attach the ground strap to a different ground point. Repeat the process until

the ground resistance is below 3Ω.

If the multimeter reads “MΩ” or “KΩ”, typically,

one of the accessories is still on.

Turn Off Accessories

aIr CUshIon seaT -

ADjUSTABLE FOR HEIGHT

(Bostrom 914 Series, National 2000 Series, or equivalent)

aIr CUshIon seaT -

ADjUSTABLE FOR HEIGHT

(Dura-Form or equivalent)

benCh seaTs -

ADjUSTABLE FOR DISTANCE TO THE STEERING WHEEL

(Manufacturer Standard or equivalent)

Typical adjustable Truck seats