Connector wiring information – Laurel Electronics LAUREATE SERIES DPM User Manual
Page 6
4.
CONNECTOR WIRING INFORMATION
4.1
CONNECTOR LOCATION
The connectors are the screw terminals that plug into the mating jack mounted on the printed
circuit board. P3 is either a 6 conductor phone plug for RS-232 and RS-485 or a 30 pin, mass
termination, edge connector for parallel BCD.
4.2
J1 - POWER AND DIGITAL CONTROLS
AC HI (+DC HI)
AC LO (DC RET)
EARTH GROUND
DIGITAL INPUT B (+5V OUT)*
DIGITAL INPUT A*
DIGITAL GROUND
4.3
J5 - SIGNAL INPUT
-EXCITATION
+EXCITATION
- SIGNAL INPUT
+SIGNAL INPUT
+
-
+
-
in
out
out
in
Signal Source
DC & PROCESS
- EXCITATION
+ EXCITATION
- SIGNAL INPUT
+SIGNAL INPUT
RTD ( 2-WIRE )
-24V EXCITATION
+24V EXCITATION
- SIGNAL INPUT
+SIGNAL INPUT
Signal Source
2 WIRE PROCESS TRANSMITTER
+
-
RTD ( 3-WIRE )
- EXCITATION
+ EXCITATION
- SIGNAL INPUT
+SIGNAL INPUT
-10VEXCITATION
+10V EXCITATION
-SIGNAL
+SIGNAL
STRAIN GAUGE
RTD (4-WIRE)
- EXCITATION
+ EXCITATION
- SIGNAL INPUT
+SIGNAL INPUT
THERMOCOUPLE
- SIGNAL INPUT
+SIGNAL INPUT
SIGNAL HIGH
NC
SIGNAL LOW
SIGNAL HIGH
AC (TRUE RMS)
-4-
20 ,200, 660V INPUTS
AC NEUTRAL
.2, 2V, CURRENT INPUTS
1
6
1
6
J1
1
3
1
4
J2
J3
J4
J5
6
1
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
*Note:
Non-isolated digital control inputs
A and B are menu selectable for Tare,
Peak Display, Hold, or Reset and exter-
nal control of decimal points.
Digital Input B selected - Jumper "h"
+5V Output selected - Jumper "g"
1
2
3
4
5
6
6
1
- QLS Quad Output 4-20 mA Current Loop - Datasheet (3 pages)
- QLS Quad Output 4-20 mA Current Loop - Manual (8 pages)
- LTS6 - Datasheet (3 pages)
- LTS6 - Manual (24 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Duty Cycle Input (4 pages)
- LT SERIES TRANSMITTERS PULSE INPUTS (40 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Position or Rate from Quadrature Encoders (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Average Time of Periodic Events (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Time of Single or Accumulated Events (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for AC Phase Angle & Power Factor (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Ratio (4 pages)
- LT: 4-20 mA & Serial Data Transmitter-Totalizer for 0-1 mA, 4-20 mA or 0-10V Process Signals (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Dual Channel Pulse Totalizer Input (4 pages)
- LT: Ethernet & 4-20 mA Output Transmitter for Frequency, Rate or Period Input (4 pages)
- LT SERIES TRANSMITTERS ANALOG INPUT (40 pages)
- LT: 4-20 mA Current Loop Transmitter for Resistance Input in Ohms (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Pt100, Cu10 and Ni120 RTD Input (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Thermocouple Types J, K, T, E, N, R, S (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Load Cell & Microvolt Signals (4 pages)
- LTE SERIES TRANSMITTERS ANALOG INPUT (40 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Strain Gauge & Potentiometer Input (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for Process Signals (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for AC RMS Voltage or Current Input (4 pages)
- LT: 4-20 mA & Serial Data Output Transmitter for DC Voltage or Current Signals (4 pages)
- LTE SERIES TRANSMITTERS PULSE INPUT (40 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Duty Cycle Input (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Position or Rate from Quadrature Encoders (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Average Time of Periodic Events (5 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Time of Single or Accumulated Events (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for AC Phase Angle & Power Factor (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Ratio (5 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter & Totalizer for 0-1 mA, 4-20 mA or 0-10V Signals (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Dual Channel Pulse Totalizer Input (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Frequency, Rate or Period Input (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Resistance in Ohms (4 pages)
- LTE: Ethernet & 4-20 mA Output RTD Transmitter for Pt100, Cu10 and Ni120 RTD Input (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Thermocouple Types J, K, T, E, N, R, S (4 pages)
- LTE: Ethernet & 4-20 mA Transmitter for Load Cell & Microvolt Signals (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for Process Signals (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for AC RMS Voltage or Current (4 pages)
- LTE: Ethernet & 4-20 mA Output Transmitter for DC Voltage or Current (4 pages)
- LTSE6 - Manual (25 pages)
- LTSE6 - Datasheet (3 pages)
- MAGNA Series Large Digit Displays (4 pages)
- M-35 Microminature Process Meter (2 pages)