-21-
DIGIT SELECT KEY
VALUE SELECT KEY
Press the
key to
display SEtuP. (Basic setup)
See Section 9, Page 10 for
detailed description of selec-
tions for digits 1 through 5.
1 2 3 4 5
1 2 3 4 5
Press the
key to display
SCALE (Scale factor).
Press
to display value
and select left digit. Press
again to select another digit.
Use
to set digit values.
Set value and decimal to 1.0
(1.0000, 01.000, etc)
Press the
key to
display dEcPt (Decimal
point).
Press
to display location
of decimal point.
Press the
key to display
OFFSt (Zero offset).
Use
to set digit values.
Set value to 00.000. Deci-
mal point is fixed by Dec.Pt.
Press
to display value
and select left digit. Press
again to select another digit.
Press the
key. Continue to press
(or
and simultaneously) until
rESEt is displayed. The meter will now go to the operating mode and display the value of the
input signal.
Press
until dC U
(dc Volts) is displayed
Press the
key to display
InPut (Input type selection).
Note: Selection of input type
& range must match jumper
selection in Section 11.1
Press
to select 0.2V,
2.0V, 20.0V, 200.0V, 660.0V
or dC A (DC Amps) is dis-
played.
or 2.0a, 20.0a, 200.0a
(milliamps) or 5.0A (Amps)
Press to change decimal
point location.
Press
to select value for
flashing digit.
Digit 1:
"0"= 20,000 cts. full scale
"3"=2,000 cts. full scale
Digit 4:
"0" = scale and offset method
MENU KEY
Press
to display status
and select left digit. Press
again to select another
digit. Selected digit will flash.