Maglock/alarm, Alarm maglock, Auxillary output power for optional devices – Controlled Products Systems Group LA400-S User Manual
Page 20

PHOTO-ELECTRIC CONTROLS
MODEL
DESCRIPTION
VOLTAGE
CPS-LN4
AOMRON
SENSING EDGES
MODEL
DESCRIPTION
VOLTAGE
G65MG0204
G65MG0205
G65MGR205
G65MGS205
20
Z22
R91
CLOSE
EDGE
R94
R92
R93
L1
R1
R2
Z1
K5
Ø14GPØ89ШE
Ш14LGШ89ШE
Ш14SKШ89ШE
K6
K2
F3
10A 32V
D1Ø
OPEN EDGE/
PHOTO
OPEN
PHOTO
CLOSE
PHOTO
J18
R227
R2Ø7
Z2Ø
R223
P1
Z9
Z8
F2
F6
D4
D2
R9
C64
JMPR1
R224
U4
P2
J1
J19
SINGLE
BUTTON
CONTROL
INPUTS
FORCE
BIPART
DELAY
TIMER TO
CLOSE
MIN
MAX
OFF
MAX
OFF
MAX
OPEN
SINGLE BUTTON
RESET
STOP
SHADOW
S1
INTERRUPT
CHGR
OVLD
COM
COM
COM
FUSE
OPEN
LOOP
INPUTS
POWER
BATT 1
BATT 2
F1 20A 32V
R35
D9
Z3
Z4
U3
D1
D27
F5
C11
C13
C12
D15
C2
R4
R1Ø1
R1ØØ
R9Ø
Q9
K1
R196
Q22
D8
K3
K4
D21
D22
C4
ACCESSORY
OVLD
D6
JMPR2
MOV1
MOV2
DB1
U2
Z12
24 VAC/
SOLAR
INPUT
GATE 2
ACCESSORY
POWER
MAGLOCK
ALARM
GATE 1
C
C
NC
NO
NO
GRN
WHT
YEL
BLU
RED
BRN
GRN
WHT
YEL
BLU
RED
BRN
F4
10A 32V
F7
24V
24V
COM
OVLD
OVLD
SWITCHED
ACCESSORY
POWER
TIMER
RUNNING
GATE 2
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
LEARN
LIMITS
DIAGNOSTIC
GATE 1
J4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
OFF
OFF
SINGLE
NO
NO
ON
ON
DUAL
NC
NC
LEARN
XMITTER
S8
1 2 3 4 5
O
N
2
1
Flashing Strobe
(optional)
Siren
(optional)
(optional)
Alarm
Maglock
When enabled, the maglock output is activated (energized) while the gate
is in motion.
Auxillary Output Power for Optional Devices
The alarm output provides a switch to turn on an external flashing device
and/or an internal audible alarm, when activated. The alarm is activated
by two sequential obstructions in either direction.
Fault Alarm
Solenoid Lock
Maglock
(optional)
Accessory
Power
(2) +24Vdc Outputs (P13 and P12) have
been provided for optional devices
MAGLOCK/ALARM
Emitter, receiver and mounting brackets - 30' (9 m) Ranges
24 Volt Photocell/Electric Eye - 30' (9 m) Ranges
+24Vdc
+24Vdc and 24Vac
Miller MG020 2-wire electric edge for gates. Sensitized on three sides. Requires
mounting channel.
Miller MG020 2-wire electric edge for gates. Sensitized on three sides. Requires
mounting channel.
Miller MGR20 2-wire electric edge in 5' (1.5 m) lengths for 2" (5 cm) round post.
Miller MGR20 2-wire electric edge in 5' (1.5 m) lengths for 2" (5 cm) square post.
+24Vdc and 24Vac
+24Vdc and 24Vac
+24Vdc and 24Vac
SAFETY ACCESSORIES FOR SECONDARY ENTRAPMENT PROTECTION
The following devices are acceptable for Safety Accessories for secondary entrapment protection. These devices have been
tested with the LA400 to meet the requirements of UL325 and UL991.