LCD Display References

LCD MSG

Meaning

Page 41

TS Ref #s

Error Messages

ERR AC
LOW

Indicates that the is 24 VAC supply to the VFlex Board is too low from the
115/230 power supply.

1, 3, 20

ERR AC
HIGH

Indicates that the is 24 VAC supply to the VFlex Board is too high from the
115/230 power supply.

1, 3, 20

ERR AC
NO AC

Indicates that there is no 24 VAC supply detected to the VFlex Board from
the 115/230 power supply.

1, 2, 4,
20

ERR CHRG
HIGH

Potential problem with the charging voltage from the control board.

1, ?

ERR CHRG
CHECK 4A

a) 4 Amp Fuse is blown
b) There is a problem with the batteries or the control board.

18, ?

ERR BAT
LOW

The battery is low

1, 2, 3,
4

ERR EPS2
WRONG

The EPS (Electronic Position Sensor) has one of the following conditions:
a) The EPS is not properly adjusted b) The EPS has a potential connection
problem c) The EPS has the wrong cable harness

?

ERR EPS2
MISSING

Missing or damaged EPS2 cable harness.

14, 17

ERR ___
LIMIT

Indicates that the open

“OPN”

, close

“CLS“

or both

“NO“

limits are cleared

and need to be set.

6

ERR FUSE
15 AMP

15 Amp motor fuse is blown

7, 11, 12

ERR EMI
NO EMI

No EMI board detected

15

ERR EMI
NO FUSE

4 Amp main fuse is blown on Power Supply Panel Assembly

2

ERR EMI
NO AC

There is no AC voltage detected from the EMI Board

20

ERR EMI
Unknown

There is a problem with the communication between the EMI Board and the
VFlex Board.

21

ERR EMI
PROTECT

Lightning strike protection for the EMI Board, behind the Power Supply
Panel Assembly, needs to be replaced

?