Troubleshooting, Lcd msg, Multi meter displays – Controlled Products Systems Group L3NX User Manual
Page 41: Board settings messages, Lcd display references, Meaning
![background image](/manuals/334984/41/background.png)
VIKING TECHNICAL SUPPORT 1.800.908.0884
3 9
TROUBLESHOOTING
LCD Display References
LCD MSG
Meaning
Page 41
TS Ref #s
Multi Meter Displays
MOT AMP
__._ A
This is the motor current amperage during operation
MOT VOLT
__._ VDC
This is the actual motor voltage during operation
AC VOLT
__._ VAC
This is the actual low voltage AC to the Control Board from the transformer
CHARGE
__._ VDC
This is the charging voltage to the batteries
BAT VOLT
__._ VDC
This is the charging voltage when Battery Switch is OFF or the battery
voltage when the low voltage AC is discontinued to the Control Board
Board Settings Messages
EPS2
___% ERR
Indicates that the Electronic Positioning Sensor (EPS) needs to be tuned.
Error rate is displayed as a percentage
Speed
xx%
Shows the percentage of speed set by the Speed adjustment on the control
board. (pg. 24)
OVERLAP
_._ SEC
Shows the number of seconds set by the Overlap Adjustment on the con-
trol board.
This feature is not available on slide gate operator models
ODS SENS
___%
Shows the amount of force required to trip the obstruction sensor. (pg. 26)
TIMER
__ SEC
Shows the time delay to hold the gate open at the limit open position,
before starts closing the gate. (pg. 24)
HEATER
__ OFF
The Integrated Heater is disabled for the open
“OPN”
and/or close
“CLS”
limits (pg. 27)
HEATER
__ ON
The Integrated Heater has been enabled to turn on at the open
“OPN”
and/
or close
“CLS”
limits (pg. 27)
“*”
will be displayed while it is heating
LOCK MOD
OFF
The Lock Mode feature is turned OFF (pg. 27)
LOCK MOD