Audible Alarm Reset Switch Installation
Manual Reset for the Audible Alarm

• UL325 standard requires an audible alarm to go off after two consecutive events

detected by the primary entrapment protection of the gate operator (obstruction
sensor).

• The audible alarm will continue to sound for 5 minutes or until a stop command

gets actuated.

• The Stop command can be actuated in three different forms:

1. Using the Built in Stop switch on the Control Box or;

2. Using an External Stop button within the sight of the gate, away from moving

parts of the gate and out of reach of children.

a. Controls intended for user activation must be located at least six feet (6’)

away from any moving part of the gate and where the user is prevented from
reaching over, under, around or through the gate to operate the controls.
Outdoor or easily accessible controls shall have a security feature to prevent
unauthorized use.

b. The Stop and/or Reset button must be located in the line-of-sight of the gate.

Activation of the reset control shall not cause the operator to start.

3. Using the Reset Button on the operator that is externally accessible from the

covers Access Door.

IMPORTANT SAFETY INFORMATION

!

WARNING! Not Following these instructions may cause severe injury or death.

Warning Placard Installation

• All Warning Placards must be installed

where visible in the area of the gate.

• A minimum of two placards shall be in-

stalled.

• A placard is to be installed in the area of

each side of the gate and be visible.